Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transl Vis Sci Technol ; 11(11): 14, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36394844

RESUMO

Purpose: In previous research the EyeQ item bank, which measures vision-related quality of life (Vr-QoL), was calibrated for future use as a computer adaptive test (CAT). The aim of the current study was to define optimal administration rules. Methods: CAT simulations were performed using real responses. Patients (N = 704; mean age, 76.2 years), having macular edema completed the EyeQ. Four CAT simulations were performed, which were set with different administration rules regarding length, accuracy level and the association with best health, which means the test was aborted after the first 4 responses of having no complaints. Results: The CATDefault showed a mean test length of 6.9 and 15.1% unreliable estimations. Extending the test length to 15 items (CATAlt1) resulted in a mean test length of 7.3 and slightly decreased the percentage unreliable estimations (11.5%). Under CATAlt2, the percentage unreliable estimations was 15.1% and the mean test length was 9.7. Percentages of floor/ceiling effects for CATDefault, CATAlt1, and CATAlt2 were 3.1, 3.0, and 3.1, respectively. CATBestHealth reduced the mean test length to 5.9 and showed 18.2% unreliably estimated patients, of which 14.2% had floor/ceiling scores. Conclusions: This study shows that the CATBestHealth provided reliably estimated ability scores, with a negligible increase in the number of unreliably estimated patients and ensures that patients having little or no vision-related quality of life problems are minimally burdened with completing items. Translational Relevance: The computer adaptive test EyeQ, set with optimal administration rules, can now be used for the computer adaptive assessment of vision-related quality of life in patients suffering from exudative retinal diseases in ophthalmic clinical practice.


Assuntos
Edema Macular , Qualidade de Vida , Humanos , Computadores , Simulação por Computador
2.
Transl Vis Sci Technol ; 11(4): 5, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35380613

RESUMO

Purpose: This study aims to develop an item-bank to measure vision-related quality of life (Vr-QoL) and subsequently calibrate this set of items. Methods: Three Vr-QoL instruments were searched for suitable items to be added in the EyeQ. Patients who received antivascular endothelial growth factor treatment for various retinal diseases involving macular edema were included in the study and completed the 47-item EyeQ. Item response theory (IRT) was used to calibrate the EyeQ items, which was performed multiple times in subsets as a novel approach, containing 80% of the data. Differential item functioning (DIF) was evaluated for various variables. Results: Responses of 704 patients were used in analysis. One item violated the local independence IRT-assumption and showed a high percentage of missing values, after which this item was deleted from the item-bank. The data of the five subsets fitted the graded response model adequately, and no DIF was detected for items between subsets, after which mean item parameters were calculated. Item fit statistics were found to be good. DIF was detected for gender, age, and administration mode by the patient (independently vs. with help), this involved three items, which all showed negligible impact on total scores. Conclusions: Because of separate calibrations of the EyeQ in multiple subsets, a high robustness of item parameters is expected. Translational Relevance: The calibrated EyeQ can now be used for the assessment of Vr-QoL in patients suffering from exudative retinal diseases and is promising for use as a computer adaptive test.


Assuntos
Qualidade de Vida , Doenças Retinianas , Calibragem , Etnicidade , Humanos , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...